Three Phase LED Track Accessories: Connectors, Joints and Kits for Professional Systems

Showing 1-7 of 7 item(s)

Three phase track accessories are not an optional extra. Without a connector you cannot turn a corner, without a feed there is no current and without an end cap the profile stays open, so they belong in the system from the first quote.

Everything in this family is compatible with three phase track, the system with three circuits that lets you switch groups of spotlights separately.

Key differences between three phase and single phase track accessories

The three conductor three phase connector carries three phases plus neutral and earth, against the single circuit of the single phase system. That difference in poles means the parts are not interchangeable, because each lighting system has its own family.

Modular three phase installation goes up just as fast, but it does require respecting the orientation of the profile. The independent three phase circuits only work if every section goes in with the same phase order.

Why the left and right connectors are different in three phase

Three phase track is not symmetrical. The earth conductor sits on a fixed side of the profile, so when you turn 90 degrees the corner can fall to the left or to the right.

That is why the left and right type L three phase track connector comes in two references. Picking the wrong one crosses the phases and the part will not go in. The angled three phase track connector follows the same handedness.

To know which to order, look at the run from under the rail and follow the direction of the current. If the branch goes off to your left, you need the left hand one.

Connector and joint types for three phase track

The type I straight joint three phase track connector extends the rail in line and is the most common straight joint. The type T three phase track connector opens a side branch off the main run.

The flexible three phase track joint solves a change of direction on runs that are not at 90 degrees, with a length of cable between the two openings.

Part Function What to watch
Type I Straight joint Extends the rail in line
Type L 90 degree corner Ordered left or right handed
Type T Branch Takes a side branch
Flexible Free angle Curved or irregular runs
End cap Closure Finishes the end of the profile

L I flexible and end caps for every configuration

The three phase track end cap closes the end and prevents contact with the conductors. The sealed version adds a gasket for damp premises or areas where water runs.

The three phase track adapter is the part that clips the spotlight onto the profile and passes it the chosen phase. The three phase rail connector splits the three circuits at the joint without losing continuity.

Three phase track extension accessories let you lengthen the installation later. The parts of the complete three phase system are sold individually so you order only what is missing. On every product you can download the data sheet with the dimensioned drawing.

Suspension kits and power feeds for three phase track

The side feed for three phase track enters through the end of the rail and takes phase, neutral and earth back to the board. It is the part that serves all three circuits at once.

A safe three phase electrical connection depends on keeping the phase order along the whole run. A change of order between sections leaves spotlights lit on the wrong circuit.

Surface installation vs suspended system

Surface mounted three phase track screws straight to the ceiling and needs nothing more than plugs and screws. The 1m suspended three phase track kit drops the profile by one metre when the ceiling is high or will not take direct fixing.

The 1m suspension kit includes the adjustable steel cables and the ceiling trim. The black and white suspended three phase track kit covers the black and white finish available across both catalogue lines.

The price of a three phase track accessory stays well below the cost of a spotlight, so it is better to order a spare than to stop the job for one part.

The rails and spotlights that complete the project are in LED track lighting, and if your installation runs a single circuit the equivalent parts are in accessories for LED rail.

Frequently asked questions about three phase track accessories

Why is there a left and a right L connector in three phase track?

Because the profile is not symmetrical and the earth conductor always sits on the same side. Depending on which way the corner turns you need one reference or the other, and they cannot be swapped.

Are three phase track accessories compatible with single phase track?

No. The number of poles is different and the part will not even fit mechanically. Each system has its own complete family of connectors and kits.

Which suspension kit do I need to hang a three phase track?

The one metre kit covers most high ceilings and comes with adjustable cables, so you can shorten them on site. It is worth checking the data sheet so the finish matches the colour of the rail.

What is the flexible joint for in a three phase system?

It joins two sections at an angle that is not 90 degrees. It carries a cable between the two openings that absorbs the turn without forcing the profile.

How many independent circuits does a three phase connector allow?

Three, one per phase. Each spotlight is assigned to a circuit with the selector on its adapter, and from the board they switch separately.

Do three phase accessories come in black and white?

Yes, both lines are available across the family. It is worth keeping the same colour on rail, connectors and kits within a continuous run.